The fans are for supplying pressurized air that required to system or boilers, we called them as forced draft fans(FD) or multi-purpose centrifugal fans.
When it is in balanced ventilation, the forced draft fan must overcome all resistance from the entrance of air duct to the furnace. It includes the resistance of air preheater, air supply duct, grate and fuel layer. During positive pressure ventilation, forced draft fan (FD) overcome all the resistance of smoke and air duct from the entrance of the air dust. This includes all flue resistance of air preheater, air supply duct, grate, fuel layer and chimney exit.
Most of the time, use the forced draft fans in boilers. Install it in front of the boiler air preheater. It sucks the air from the atmosphere. And then sends the air to the air preheater and heated to the requested temperature. Use part of it as the secondary air of the boiler and directly send to the furnace of the boiler through the burner. But the other part enters the pulverized coal preparation system as a desiccant. Or as primary air, convey coal powder to the furnace through the burner (depleted air powder feeding system), or as tertiary air directly into the furnace through the burner (hot air powder feeding system)
Below is the menu list of products technical details, please click and select the product you required and to see more details of the product.
Induced Draft:- A fan is used to extract the air from boiler post combustion to exhaust through the chimney. This is called ID fan. 1. It located in between the Boiler/ESP and the chimney/stack. Suction from ESP / Boiler and discharge to the stack. 2. Used to exhaust gases to atmosphere through chimney. 3. In balanced draft used to maintain slight negative pressure (-10 mm Hg typically) with respect to atmosphere to prevent pressurization of boiler(reduces the risk of explosion.). 4. Size is largest as it exhaust all air (secondary air and primary air) and is first to start as is necessary for safe boiler operation to prevent pressurization of boiler.
Forced draft:- A fan is used to force air into the boiler to provide more air for combustion. This is called FD fan, the location near mills and discharges directly to wind box of boiler for uniform air distribution. 1. Suction from atmosphere and discharge to the wind box of the boiler. 2. Used to provide secondary air that is the main air supply for fuel combustion. 3. It pressurizes boiler so is started only after the ID fan is started. Is much smaller than ID fan.
No. 6,Yingtong industrial road,Guangdong,China
13611967526@163.com
+86 (760)89980693
Add:No.: 6,Yingtong industrial road,
Shalang industrial area,China
TEL:+86 (760)89980693
http://www.centrifugal-fan.com/
Forced/Inducted draft fans 1 Energy-saving analysis of boiler forced/inducted draft fans in thermal power plants 1.1 The importance of energy-saving design.In the thermal power generation technology, the boiler forced/inducted draft fan is an indispensable auxiliary device to ensure the normal operation of the generator set, and the electricity cost brought by the boiler fan makes it occupy a prominent position in the strategy of energy saving and emission reduction. Industry data shows that among the various operating equipment of thermal power plants, the electricity consumption of boiler fans can account for more than 40% of the electricity cost of the entire power plant. Once the boiler fan selection, technical parameter control, and equipment operation and maintenance problems occur, it will not only increase the comprehensive cost of power generation and the operating cost of thermal power plants, but also cause a series of problems such as waste of resources and increased non-functional consumption[1] . From an energy-saving perspective, technicians need to fully consider the energy-saving scheme of boiler fans, and take the current energy consumption status of boiler forced/inducted…
China is a large industrial country as well…
© Copyright 2020.Golta Industries Co.,Ltd. All Rights Reserved.